| Component - Plastics | E116656 | |
| NOK CORP | ||
| ISOHARA FACTORY, 831-2 KAMI-SOHDA, ISOHARA-MACHI, KITAIBARAKI-SHI IBARAKI-KEN 319-1593 JP | ||
| IR#A-@(a) | ||
| Polyurethane (PUR), furnished as finished parts | ||
| Min Thk | Flame | RTI | RTI | RTI | |||
| Color | (mm) | Class | HWI | HAI | Elec | Imp | Str |
| GN | 0.40 | HB | - | - | 50 | 50 | 50 |
| NC | 0.80 | V-2 | - | - | 50 | 50 | 50 |
| NC, RD | 3.0 | V-2 | - | - | 50 | 50 | 50 |
| NC, RD, WT | 6.0 | V-2 | - | - | 50 | 50 | 50 |
| Comparative Tracking Index (CTI): | - | Inclined Plane Tracking (IPT): | - |
| Dielectric Strength (kV/mm): | - | Volume Resistivity (10x ohm-cm): | - |
| High-Voltage Arc Tracking Rate (HVTR): | - | High Volt, Low Current Arc Resis (D495): | - |
| Dimensional Stability (%): | - |
| # - | A two digit number 88-99 denoting hardness of the material. |
| (a) - | A digint number 0-2 denoting a sort of nucleating agent. |
| @ - | A digit number 0-9 denoting color of the material. |
| ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 small-scale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL. |
|
Report Date:
1990-12-28 Last Revised: 2003-10-24 |
© 2015 UL LLC |
| IEC and ISO Test Methods | ||||
| Test Name | Test Method | Units | Thk (mm) | Value |
| Flammability | IEC 60695-11-10 | Class (color) | 0.40 | HB75 (GN) |
| 0.80 | V-2 (NC) | |||
| 3.0 | V-2 (NC, RD) | |||
| 6.0 | V-2 (NC, RD, WT) | |||
| Glow-Wire Flammability (GWFI) | IEC 60695-2-12 | C | - | - |
| Glow-Wire Ignition (GWIT) | IEC 60695-2-13 | C | - | - |
| IEC Comparative Tracking Index | IEC 60112 | Volts (Max) | - | - |
| IEC Ball Pressure | IEC 60695-10-2 | C | - | - |
| ISO Heat Deflection (1.80 MPa) | ISO 75-2 | C | - | - |
| ISO Tensile Strength | ISO 527-2 | MPa | - | - |
| ISO Flexural Strength | ISO 178 | MPa | - | - |
| ISO Tensile Impact | ISO 8256 | kJ/m2 | - | - |
| ISO Izod Impact | ISO 180 | kJ/m2 | - | - |