| Component - Plastics | E56953 | |
| Panasonic Corporation of North America | ||
| Product Safety & Compliance Dept, Two Riverfront Plaza, 9th Fl, Newark NJ 07102-5490 | ||
| UE600 1000 | ||
| Unsaturated Polyester (UP), potting compound, furnished as two liquid components | ||
| Min Thk | Flame | RTI | RTI | RTI | |||
| Color | (mm) | Class | HWI | HAI | Elec | Imp | Str |
| NC | 1.4 | V-0 | 2 | 0 | 50 | 50 | 50 |
| 3.4 | V-0 | 1 | 0 | 50 | 50 | 50 |
| Comparative Tracking Index (CTI): | 2 | Inclined Plane Tracking (IPT): | - |
| Dielectric Strength (kV/mm): | - | Volume Resistivity (10x ohm-cm): | - |
| High-Voltage Arc Tracking Rate (HVTR): | 2 | High Volt, Low Current Arc Resis (D495): | 5 |
| Dimensional Stability (%): | - |
| ANSI/UL 94 small-scale test data does not pertain to building materials, furnishings and related contents. ANSI/UL 94 small-scale test data is intended solely for determining the flammability of plastic materials used in the components and parts of end-product devices and appliances, where the acceptability of the combination is determined by UL. |
|
Report Date:
1978-12-26 Last Revised: 2003-10-24 |
© 2015 UL LLC |
| IEC and ISO Test Methods | ||||
| Test Name | Test Method | Units | Thk (mm) | Value |
| Flammability | IEC 60695-11-10 | Class (color) | 1.4 | V-0 (NC) |
| 3.4 | V-0 (NC) | |||
| Glow-Wire Flammability (GWFI) | IEC 60695-2-12 | C | - | - |
| Glow-Wire Ignition (GWIT) | IEC 60695-2-13 | C | - | - |
| IEC Comparative Tracking Index | IEC 60112 | Volts (Max) | - | - |
| IEC Ball Pressure | IEC 60695-10-2 | C | - | - |
| ISO Heat Deflection (1.80 MPa) | ISO 75-2 | C | - | - |
| ISO Tensile Strength | ISO 527-2 | MPa | - | - |
| ISO Flexural Strength | ISO 178 | MPa | - | - |
| ISO Tensile Impact | ISO 8256 | kJ/m2 | - | - |
| ISO Izod Impact | ISO 180 | kJ/m2 | - | - |
| ISO Charpy Impact | ISO 179-2 | kJ/m2 | - | - |